FIRE ALARM SYSTEM |
| Analogue Fire Panel |
Conventional Fire Panel |
 |
 |
| Design features: |
Design features : |
The FX6000 range is a high specification analogue fire system available in various loop configurations. It combines sophisticated functionality with simple operation and very aesthetically pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for
a diverse range of projects from sheltering housing to large office developments and industrial applications |
JSB FX2200 range of panels provides a solution
to any conventional system requirement. The advance
features including a simple “ one-shot” user test facility,
class change contacts, battery voltage High/Low alarms
and change temperature compensation, all included as
standard to ensure ease of use and high reliablility. Attention
to detail is emphasised by the neat log book holder
feature, allowing essential records to be stored close to
hand, ready for quick reference. |
System Overview:
- The range consists of single, two and four loop
panels and a wide range of compatible detectors,
call points sounders, beacons, repeater panels and
interfaces
- Panels are available in a choice of colours (Standard
light grey and graphite)
- available with or without a built-in printer
- All panels have integral power supplies and batteries,
both are supplied with the panel as standard
*
- For heavily loaded systems or systems requiring
extended autonomy in the event of a main failure,
versions are available with extended batter capacity
Detection Capacity :
- Up to 200 addresses per loop which can be a mixture of
call points, detectors, interfaces, loop sounders or repeaters
- To comply with EN 54 requirement no more than 512
addresses should be connected to a single panel
|
System Overview:
- Flexible, high specification conventional panel
suitable for a wide range of building type and sizes
- Choice of 1, 2 , 3 or 8 Zone Panels
- Supplied complete with battery for 24 hours standby.
Battery charger has temperature compensation as standard
- Matching 8 zone repeater panel, for use with 8 zone and 1 / 4 zone configured panel.
- Stylish and robust compact panel with simple 5 button
keypad control of all functions
- Simple “one-shot” weekly user test with auto-reset facility
- Comprehensive power, fire and fault LED indicators and
integral piezo buzzer for on-board fire or fault indication
- Battery high / low voltage alarm facility
- Two separate alarm lines on 1, 2 and 4 zone panels.
Maximum rate load of 150mA ( 1/2 zone) or 400mA (4 zone) per line
- Alarm lines are monitored for open circuit and short circuit faults
|
Smoke Detector
FX523 Conventional Optical Smoke Detector
SD1000 Conventional Optical Smoke Detector
FX521 Conventional Ionisation Smoke Detector
Specification
Voltage range : 16 - 32 V DC
Alarm Current : 10 - 100mA
Quiescent : 100uA @ 24V DC
Storage Temperature : -20 C to + 75 C
Operating temperature : 0 C to + 75 C
Humidity : 95%
Coverage : 100 sq. mtr
Colour : White
Weight : 135 gm
|

|
|
Smoke Detectors used for fast burning, high energy fires.
+ Petrochemical or solvent stores,
+ Electrical switch rooms,
+ Computer rooms.
A mixture of optical and ionisation
sensors can be used to ensure coverage areas of high
value,rooms |
| Manual Break Glass Unit |
|

|
BG1000 Surface Callpoint
MBG914 Surface Callpoint
MBG913 Flush Callpoint
Specification
Supply voltage : 24V DC
Electrical monitoring : 470R series resistor
Colour : White
Operating temperature : 20 C to + 80 C
|
|
| Sounder |
|

|
FX006 6” Internal 24V bell
FB1000 Series
FB6 6” Internal 24V Bell
FB8 8” Internal 24V Bell
|
|
| Beam Detector |
|

|
The reflective beam detector consists of a single unit, incorporating an infra-red transmitter and receiver. it is mounted so that beam will project between 0.3
and 0.6 meter below and parallel to the ceiling and is reflected by a prism unit on the opposite wall
Key Features
- Single compact housing
- Soft addressed ( loop powered beam)
- Simple beam alignment
- Selectable alarm thresholds
- Area coverage up to 1500m2
- Automatic compensation
- LPCB certification
|
|
| Battery operated Smoke Alarm(Ionization Sensor) |
|

|
An affordable way to add additional smoke alarms to any home
safety plan. Full size smoke alarm has a 5” base.
Features
- Ionization Sensor
- Battery Power Indicator
- Low Battery Warning “Chirp”
- Missing Battery Tab
- Hinged Cover for Easy Battery
Replacement
- 9V Battery Included
|
|
| Fire Alarm Bell |
|

|
6” & 8’’ Internal 24V bell
6’’ & 8’’ Weatherproof bells
Specification
A wide range of bells comprising internal and external
version. Weather proof back box available on request
|
|
| |
|
 |
|
 |
Tel: 24815831, 248 21230,
Fax: 24813992
email: asteks@omantel.net.om |
|
 |
|